Whether you only need a few measurements taken or you have a large measurement project you’re working on, Compass Technology Group can help. We offer typical measurements on any of our devices as well as unconventional ways of using our systems to measure odd specimens. Contact us today with the size/shape of your specimen and what you want to measure. We can assist you in choosing the best way to measure it and get the data you need. 

WR-4200 Waveguide Measurements

WR-4200 Waveguide Measurements include:

  • Measurements
    • Lowest Frequency – 150 MHz
    • Highest Frequency – 325 MHz
  • Sample Size
    • 42″ to 5.25″ 
  • Data
    • S-parameters available upon request
    • Complex Permittivity
    • Permeability
    • Sheet Impedance

*May require additional charge per sample for specimen preparation.

Table-Top Measurements

Table-Top Measurements include:
  • Dual pol
    • Lowest Frequency – 2 GHz
    • Highest Frequency – 20 GHz
  • Sample Size
    • ~6″ to 12″ square 
  • Data
    • S-parameters available upon request
    • Complex Permittivity
    • Permeability
    • Sheet Impedance

Slotted R-Coax Measurements

Slotted RCoax Measurements include:

  • Dual pol
    • Lowest Frequency – 60 MHz
    • Highest Frequency – 680 MHz
  • Sample Size Squares
    • 6″ x 6″ 
    • 12″ x 12″
    • 35″ x **
  • Data
    • Complex Sheet Impedance

**Second demension should be 6″ or larger

Focused Beam Basic Measurements

  • Basic measurements include:
  • Dual pol
    • Lowest Frequency – 2 GHz
    • Highest Frequency – 20 GHz
  • Sample Size
    • ~6″ to 24″ square depending on lower frequency bound
  • Data
    • S-parameters available upon request
    • Complex Permittivity
    • Permeability
    • Sheet Impedance

Millimeterwave Focused Beam

  • Dual pol
    • Lowest Frequency –  20 GHz
    • Highest Frequency – 40 GHz
  • Sample Size
    • ~6″ to 12″ square depending on lower frequency bound
  • Data
    • S-parameters available upon request
    • Complex Permittivity
    • Permeability
    • Sheet Impedance
  • Dual pol
    • Lowest Frequency –  60 GHz
    • Highest Frequency – 90 GHz
  • Sample Size
    • 3″ square or larger
  • Data
    • S-parameters available upon request
    • Complex Permittivity
    • Permeability
    • Sheet Impedance
 

RF Capacitor Measurements

RF Capacitor Measurements include:

  • Measurements
    • Lowest Frequency – 85 MHz
    • Highest Frequency – 800 MHz
    • Three orientations
  • Sample Size
    • 3″ cube
  • Data
    • Complex Permittivity

CTG has a number of new and experimental methods that it can apply. Provide your measurement requirements and we will make recommendations on how best to get what you need.

Lead Time: approximately two weeks